SITCARE: AN IOT-BASED SITTING BEHAVIOR MONITORING SYSTEM USING SENSOR FUSION

  • Kevin Sutanto
    Universitas Kristen Krida Wacana
  • Putri Caezylia Rundupadang
    Universitas Kristen Krida Wacana
  • Louie Jason Liman
    Universitas Kristen Krida Wacana
  • Jeremiah Jacob Hartadhi
    Universitas Kristen Krida Wacana
  • Yohanes Panca Sihite
    Universitas Kristen Krida Wacana
DOI: https://doi.org/10.23960/jitet.v14i3.10844
Keywords Internet of Things (IoT), ergonomics, sensor fusion, sitting behavior
Abstract Views (Last 12 Months)
16 Abstract Views
12 Downloads

Abstract

Prolonged sitting and poor sitting posture have become significant occupational health concerns among office workers, contributing to musculoskeletal disorders, fatigue, and reduced work productivity. This study proposes SITCARE, an Internet of Things (IoT) based office sitting behavior monitoring system that integrates an FSR402 pressure sensor, an MPU6050 gyroscope, and an HC-SR04 ultrasonic sensor using a sensor fusion approach. The proposed system continuously monitors sitting duration, chair inclination, and seat height, while transmitting real time sensor data to a Firebase Realtime Database for web-based visualization. In addition, an automated Telegram chatbot provides reminders to encourage regular breaks and adequate hydration. The developed system was evaluated through sensor validation, communication performance testing, system functionality assessment, and user acceptance evaluation. Experimental results demonstrated reliable sensor operation, stable cloud communication with an average round trip latency of 220 ± 50 ms and zero packet loss, as well as successful real time dashboard visualization and notification delivery. Furthermore, user evaluation involving 20 participants achieved an overall satisfaction score of 4.50 out of 5, indicating positive acceptance of the proposed system. These findings demonstrate that SITCARE provides an effective and practical IoT based solution for promoting ergonomic awareness and healthier workplace behavior among office workers.

Downloads

Download data is not yet available.

References

H. Silva, P. G. F. Ramos, S. C. Teno, and P. B. Júdice, “The Impact of Sit-Stand Desks on Full-Day and Work-Based Sedentary Behavior of Office Workers: A Systematic Review,” Hum. Factors J. Hum. Factors Ergon. Soc., vol. 67, no. 7, pp. 695–713, Jul. 2025, doi: 10.1177/00187208241305591.

B. Chandrasekaran, C. R. Rao, E. Thirunavukkarasu, R. Jadhav, P. Srivastav, and K. C. Bairapareddy, “Effectiveness of mHealth Interventions on Physical Activity and Sedentary Behavior Among Office Workers: A Systematic Review and Meta-analysis,” J. Occup. Rehabil., Mar. 2026, doi: 10.1007/s10926-026-10373-z.

I. Parés-Salomón et al., “Effectiveness of workplace interventions with digital elements to reduce sedentary behaviours in office employees: a systematic review and meta-analysis,” Int. J. Behav. Nutr. Phys. Act., vol. 21, no. 1, pp. 1–29, 2024, doi: 10.1186/s12966-024-01595-6.

D. P. Bailey, “Sedentary behaviour in the workplace: prevalence, health implications and interventions,” Br. Med. Bull., vol. 137, no. 1, pp. 42–50, Mar. 2021, doi: 10.1093/bmb/ldaa039.

A. Shariat et al., “Prevalence rate of neck, shoulder and lower back pain in association with age, body mass index and gender among Malaysian office workers,” Work, vol. 60, no. 2, pp. 191–199, May 2018, doi: 10.3233/WOR-2738.

N. Pearson and L. B. Sherar, “Sedentary behaviour and health,” in Oxford Textbook of Children’s Sport and Excercise Medicine 4e, vol. 51, no. 6, N. Armstrong and W. van Mechelen, Eds. Oxford University PressOxford, 2023, pp. 255-C18P159.

B. M. Popkin, K. E. D’Anci, and I. H. Rosenberg, “Water, hydration, and health,” Nutr. Rev., vol. 68, no. 8, pp. 439–458, Aug. 2010, doi: 10.1111/j.1753-4887.2010.00304.x.

M. C. Tsai, E. T. H. Chu, and C. R. Lee, “An Automated Sitting Posture Recognition System Utilizing Pressure Sensors,” Sensors, vol. 23, no. 13, pp. 1–21, 2023, doi: 10.3390/s23135894.

M. Martínez-Estrada et al., “A Smart Chair to Monitor Sitting Posture by Capacitive Textile Sensors,” Materials (Basel)., vol. 16, no. 13, pp. 1–15, 2023, doi: 10.3390/ma16134838.

H. Pan et al., “Automated, IMU-based spine angle estimation and IMU location identification for telerehabilitation,” J. Neuroeng. Rehabil., vol. 21, no. 1, pp. 1–15, 2024, doi: 10.1186/s12984-024-01366-1.

M. La Mura, M. De Gregorio, P. Lamberti, and V. Tucci, “IoT System for Real-Time Posture Asymmetry Detection,” Sensors, vol. 23, no. 10, 2023, doi: 10.3390/s23104830.

S. Emerson, K. Emerson, and J. Fedorczyk, “Computer workstation ergonomics: Current evidence for evaluation, corrections, and recommendations for remote evaluation,” J. Hand Ther., vol. 34, no. 2, pp. 166–178, Apr. 2021, doi: 10.1016/j.jht.2021.04.002.

S. Tahernejad et al., “Investigation of office workers’ sitting behaviors in an ergonomically adjusted workstation,” Int. J. Occup. Saf. Ergon., vol. 28, no. 4, pp. 2346–2354, Oct. 2022, doi: 10.1080/10803548.2021.1990581.

M. Kaur, J. Pal, and M. Tech Student, “Distance Measurement of Object by Ultrasonic Sensor HC-SR04,” IJSRD-International J. Sci. Res. Dev., vol. 3, no. 05, 2015, [Online]. Available: www.ijsrd.com.

K. Sutanto, A. Reyvan, and B. Harsono, “RANCANG BANGUN ALAT LATIHAN TEKNIK TENDANGAN PADA BELA DIRI TAEKWONDO BERBASIS ARDUINO,” J. Inform. dan Tek. Elektro Terap., vol. 13, no. 2, Apr. 2025, doi: 10.23960/jitet.v13i2.6200.

H. Riva and A. Setiawan, “Sistem Monitoring Dan Proteksi Overload Dengan Load Shedding Berbasis Iot Pada Instalasi Listrik Rumah Tangga,” J. Inform. dan Tek. Elektro Terap., vol. 14, no. 2, pp. 240–252, 2026, doi: 10.23960/jitet.v14i2.9242.

Cover
Published
2026-08-13
How to Cite
Sutanto, K., Caezylia Rundupadang, P., Jason Liman, L., Jacob Hartadhi, J., & Panca Sihite, Y. (2026). SITCARE: AN IOT-BASED SITTING BEHAVIOR MONITORING SYSTEM USING SENSOR FUSION. Jurnal Informatika Dan Teknik Elektro Terapan, 14(3). https://doi.org/10.23960/jitet.v14i3.10844