EVALUASI KINERJA PMT 20 kV BERDASARKAN TAHANAN ISOLASI, TAHANAN KONTAK DAN UJI VAKUM
DOI:
https://doi.org/10.23960/jitet.v13i3S1.7907Abstract Views: 108 File Views: 48
Keywords:
Pemutus Tenaga, Tahanan Isolasi, Tahanan Kontak, Uji Vakum, Gardu IndukAbstract
A circuit breaker is one of the main components in an electrical power system that functions to ensure the safety and reliability of power delivery in distribution, transmission, and generation systems. This study aims to evaluate the performance and feasibility of a 20kV medium-voltage vacuum circuit breaker based on three test parameters: insulation resistance, contact resistance, and vacuum test. The evaluation was carried out through direct observation during testing using standard measurement instruments, including the Megger S1-1068, CPC 100, and Vanguard VBT-75P. The test results show that all parameters fall within the standard value range set by the manufacturer and comply with recommendations from relevant institutions. Therefore, the tested circuit breaker is considered feasible for continued operation. This study highlights the importance of periodic testing of circuit breaker equipment as a preventive effort to avoid potential system disturbances, equipment damage, and safety hazards caused by circuit breaker failure.
Pemutus tenaga merupakan salah satu komponen utama dalam sistem tenaga listrik yang berfungsi untuk menjamin keamanan dan keandalan penyaluran energi listrik pada sistem distribusi maupun transmisi maupun pembangkit. Penelitian ini bertujuan untuk mengevaluasi kinerja dan kelayakan pemutus tenaga vakum tegangan menengah 20kV berdasarkan tiga parameter pengujian, yaitu tahanan isolasi, tahanan kontak, dan uji vakum. Evaluasi dilakukan melalui observasi langsung. Pada proses pengujian menggunakan alat ukur standar, seperti Megger S1-1068, CPC 100, dan Vanguard VBT-75P. Hasil pengujian menunjukkan bahwa seluruh parameter berada dalam kisaran nilai standar yang ditetapkan oleh pabrikan serta sesuai dengan rekomendasi instansi. Dengan demikian, pemutus tenaga yang diuji dinyatakan layak untuk tetap dioperasikan. Penelitian ini memberikan pemahaman tentang pentingnya pengujian berkala terhadap peralatan pemutus tenaga sebagai upaya pencegahan terhadap potensi gangguan sistem, kerusakan peralatan, maupun bahaya kecelakaan yang disebabkan oleh kegagalan fungsi pemutus tenaga
Downloads
References
PT. PLN (Persero), Buku Pedoman Pemeliharaan Pemutus Tenaga. Jakarta: PT. PLN (Persero), 2014. Accessed: May 22, 2025. [Online]. Available: https://id.scribd.com/document/463378857/Buku-Pedoman-PMT-Final
J. Y. Siallagan, A. Tanjung, and A. Arlenny, “Studi Kebutuhan Perencanaan Pemasangan Busbar Proteksi Pada Gardu Induk Dumai PT. PLN (Persero) UPT Pekanbaru,” J. Tek., vol. 15, no. 2, pp. 94–103, 2021, doi: 10.31849/teknik.v15i2.6623.
Y. Patasik, A. R. Sultan, A. R. Idris, and A. Rahmadani, “ANALISIS POLA OPERASI JARINGAN 20 KV PASCA BEROPERASINYA GARDU INDUKMOLIBAGUDI PLN UP3 KOTAMOBAGU,” J. Inform. dan Tek. Elektro Terap., vol. 13, no. 3, pp. 459–469, 2025.
N. Tenda, S. M. Lily s. patras, and M. Ir. Hans Tumailang, “Penyusutan daya listrik pada penyulang jaringan transmisi isimu marisa,” E-Journal Tek. Elektro Dan Komput., vol. 5, no. 1, pp. 2301–8402, 2016.
N. Y. Latif, A. W. Indrawan, N. A. Noor, A. Rahmadani, P. Negeri, and U. Pandang, “Moutong Terhadap Drop Tegangan Sistem,” vol. 13, no. 3.
Johan Hidayat and Muhammad Fatkhurrokhman, “Pemeliharaan Kubikel 20 KV di PT.Haleyora Powerindo,” Venus J. Publ. Rumpun Ilmu Tek., vol. 2, no. 6, pp. 130–149, 2024, doi: 10.61132/venus.v2i6.635.
Muhamad Sadewa and Endi Permata, “Analisis Desain Kubikel 20kV untuk Peningkatan Efisiensi dan Keandalan Sistem Distribusi Listrik,” Venus J. Publ. Rumpun Ilmu Tek., vol. 2, no. 6, pp. 116–129, 2024, doi: 10.61132/venus.v2i6.633.
PT.PLN (Persero), “Buku Pedoman Pemeliharaan KUBIKEL TEGANGAN MENENGAH Lampiran Surat Keputusan Direksi PT PLN (Persero) No. 0520-2.K/DIR/2014,” 2014, [Online]. Available: https://www.scribd.com/document/424628869/24-Buku-Pedoman-Kubikel-Tegangan-Menengah
B. Adhitya and E. Handoyo, “Pengujian Tahanan Isolasi pada Pemeliharaan Pemutus Tenaga (PMT) Kubikel Outgoing 20 kV Menggunakan Insulation Tester di Gardu Induk Bantul PT. PLN (Persero) UP2D JTY DCC 2 Yogyakarta,” Ejournal Kaji. Tek. Elektro, vol. 5, no. 2, 2020.
S. Hartanto, R. Pahlavi, and T. O. Priyono, “PENGUJIAN KINERJA PMT 20 kV PADA KUBIKEL NETTO GARDU INDUK PLTMG SENAYAN,” Teknokris, vol. 26, no. 1, pp. 45–53, 2023, doi: 10.61488/teknokris.v26i1.259.
A. Ariansyah and S. Safaruddin, “PEMELIHARAAN SWITCHGEAR DAN PENGUKURAN TAHANAN KONTAK DI VCB PADA AREA RAW MIIL Di PT. SEMEN BATURAJA (PERSERO) TBK,” JIMR J. Int. Multidiscip. Res., vol. 1, no. 02, pp. 224–231, 2022, doi: 10.62668/jimr.v1i02.430.
P. Multifeeder, K. Incoming, Z. Palit, L. S. Patras, and G. M. C. Mangindaan, “MULTIFEEDER CONFIGURATION FOR FAULT ISOLATION IN INCOMING CUBICLE”.
P. M. Firmansyah, M. Tuegeh, and H. Tumaliang, “Analytical Study of 20 kV Circuit Breakers Performance at the Substation,” pp. 1–10.
A. Aland et al., “Analisa Kinerja Circuit Breaker Saat Gangguan Pada Sisi 70 KV Di Gardu Induk Teling,” vol. 6, pp. 1–8, 2022.
P. Darminto, “Analisis Pengukuran Tahanan Kontak dan Tahanan Pertanahan Pada Pemutus Tenaga,” 2022.
A. Fikri, H. Rudito, and Usman, “Analisis Pengujian Pemutus Tenaga (PMT) Bay Punagaya Dalam Pemeliharaan Dua Tahunan di Gardu Induk Tallasa,” Jurnal.Poliupg.Ac.Id, no. September, pp. 2–6, 2021, [Online]. Available: http://jurnal.poliupg.ac.id/index.php/sntei/article/view/2813
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2025 Jurnal Informatika dan Teknik Elektro Terapan

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.