Evaluasi Kinerja Struktur Gedung Bertingkat dengan Metode Analisis Pushover (Studi Kasus: Gedung 6 Rumah Sakit Pendidikan Perguruan Tinggi Negeri (RSPTN) Universitas Lampung)
DOI:
https://doi.org/10.23960/jrsdd.v12i1.4316Abstract Views: 326 File Views: 409 File Views: 0 File Views: 0 File Views: 0 File Views: 0 File Views: 0
Abstract
The high potential for earthquake in Indonesia encourages the design of buildings to be resistant towards earthquake vibrations. The level of vulnerability to lateral forces, especially earthquake shocks, is closely related to the height of the building. Therefore, the design of multi-storey building structures must be designed by analyzing earhquake loads with the aim of preventing the building from collapsing and reducing the number of fatalities due to earthquakes. This research takes a case study at Building 6th of the State University Education Hospital of University of Lampung using a performance-based seismic design approach, which involves the use of non linear pushover analysis techniques based on ATC-40 (capacity spectrum method) and FEMA-356 (displacement coefficient method). The result of the pushover analysis are capacity curves, building displacement targets, building collapse schemes, and result of building performance evaluations against earthquake loads based on ATC-40 and FEMA-356 regulations. The analysis result show that the level of building performance in the x-direction and y-direction with the maximum total drift ratio parameter based on ATC-40 and FEMA-356 is Immediate Occupancy, so it can be concluded that the building is still able to withstand when an earthquake occurs and the risk of human loss is very small.Downloads
Download data is not yet available.
References
Applied Tecnology Council (ATC 40). 1999, Seismic Evaluation and Retrofit of Concrete Buildings. Redwood City, California, USA: DC.
Badan Standarisasi Nasional. 2019. Tata Cara Perencanaan Ketahanan Gempa untuk Struktur Bangunan Gedung dan Non Gedung (SNI 1726:2019). Jakarta: Badan Standarisasi Nasional.
Badan Standarisasi Nasional. 2020. Beban Desain Minimum dan Kriteria Terkait untuk Bangunan Gedung dan Struktur (SNI 1727:2020). Jakarta: Badan Standarisasi Nasional
Federal Emergency Management Agency. 2000, Prestandart and Commentary for the Seismic Rehabilitation of Building FEMA-356, Washington, DC.
Downloads
Additional Files
- Evaluasi Kinerja Struktur Gedung Bertingkat dengan Metode Analisis Pushover (Studi Kasus: Gedung 6 Rumah Sakit Pendidikan Perguruan Tinggi Negeri (RSPTN) Universitas Lampung)
- Applied Tecnology Council (ATC 40). 1999, Seismic Evaluation and Retrofit of Concrete Buildings. Redwood City, California, USA: DC.
- Badan Standarisasi Nasional. 2019. Tata Cara Perencanaan Ketahanan Gempa untuk Struktur Bangunan Gedung dan Non Gedung (SNI 1726:2019).
- Badan Standarisasi Nasional. 2020. Beban Desain Minimum dan Kriteria Terkait untuk Bangunan Gedung dan Struktur (SNI 1727:2020). Jakarta: Badan Standarisasi Nasional
- Federal Emergency Management Agency. 2000, Prestandart and Commentary for the Seismic Rehabilitation of Building FEMA-356, Washington, DC.
Published
2024-10-23
How to Cite
Mustofa, R. A., Bayzoni, B., Husni, H. R. and Isneini, M. (2024) “Evaluasi Kinerja Struktur Gedung Bertingkat dengan Metode Analisis Pushover (Studi Kasus: Gedung 6 Rumah Sakit Pendidikan Perguruan Tinggi Negeri (RSPTN) Universitas Lampung)”, Jurnal Rekayasa Sipil dan Desain (JRSDD), 12(1), pp. Hal. 27 – 38. doi: 10.23960/jrsdd.v12i1.4316.
Issue
Section
Makalah Ilmiah Edisi Maret 2024
License

JRSDD is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.