Pengaruh Penambahan Fiber Baja Seling dengan Volume Fraction 0,4%, 0,6% dan 0,8% terhadap Kuat Tekan dan Kuat Tarik Lentur pada Beton Mutu Normal.
DOI:
https://doi.org/10.23960/jrsdd.v4i3.402Abstract Views: 95 File Views: 92 File Views: 100
Abstract
This research was conducted to study and determine the influence of steel sling fiber 0,4%, 0,6% and 0,8% volume fraction of compressive strength and flexural strength on normal quality concrete. This study used an experimental method in the Laboratory of Material and Construction Engineering Faculty, University of Lampung. The compressive strength test specimen is a 30 cm height and 15 cm diameter cylinder and the flexural strength test specimen is a 40 cm length, 10 cm width and 10 cm height beam. The compressive strength and flexural strength test of normal quality concrete with 0,4%, 0,6% and 0,8% volume fraction held after 14 and 28 days. The maximum compressive strength and flexural strength value are at 0,6% volume fraction and decrease at 0,8% volume fraction. The maximum compressive strength is 27,5537 MPa at 0,6% volume fraction and the optimum value from polynomial trendline chart is 27,6028 MPa at 0,5754% volume fraction. The maximum flexural strength is 5,6899 MPa at 0,6% volume fraction and the optimum value from polynomial trendline chart is 5,7163 MPa at 0,5687% volume fraction. The steel sling fiber didn’t affect a high increase of the compressive strength, but this steel sling fiber had a high flexural strength which is 1733,46 MPa, so it affected a significant increase of the flexural strength test.
Keywords : compressive strength, flexural strength, fiber concrete, steel sling fiber
Downloads
References
ASTM C 78, Standard Test Method for Flexural Strength of Concrete (Using Simple Beam
with Third-Point Loading). West Conshohocken. United States.
Dipohusodo, I., 1993, Struktur Beton Bertulang. Departemen Pekerjaan Umum: Badan
Penelitian dan Pengembangan PU. Jakarta.
Felany, D., 2004, Tinjauan Kuat Desak Dan Kuat Tarik Belah Beton dengan Penambahan
Serat Tali Beneser. Universitas Sebelas Maret. Surakarta.
Mulyono, Tri. 2003, Teknologi Beton. ANDI. Yogyakarta.
Purwanto, E., 1999, Perilaku Fiber Lokal Pada Perilaku Dan Kuat Torsi Ultimit Balok Beton
Bertulang. Universitas Gajah Mada. Yogyakarta.
SNI 15-7064-2004, 2004, Semen Portland Komposit. Badan Standarisasi Nasional. Bandung.
Soroushian, P., And Bayasi, Z., 1991, Fiber Type Effects on the Performance of Steel Fiber
Reinforced Concrete, Michigan State University, Michigan, USA.
Sudarmoko, 1989, Pengaruh Penambahan Fiber pada Kelecakan Adukan Beton. Pusat Antar
Universitas Ilmu Teknik. Universitas Gadjah Mada.
Sugiyanto dan Sebayang, Surya, 2005, Teknologi Bahan. Bandar Lampung. Universitas
Lampung.
Tjokrodimuljo, K., 2007, Teknologi Beton. Universitas Gajah Mada. Yogyakarta.
Published
How to Cite
Issue
Section
License

JRSDD is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.