Kalibrasi Alat Ukur Sedimen Tersuspensi Berbasis Turbidity Sensor

Authors

  • Achmad Bagus Fakhrizal Civil Engineering Department, Faculty of Engineering, University of Lampung
  • Yuda Romdania Civil Engineering Department, Faculty of Engineering, University of Lampung
  • Endro Prasetyo Wahono Civil Engineering Department, Faculty of Engineering, University of Lampung
  • Ahmad Herison Civil Engineering Department, Faculty of Engineering, University of Lampung

DOI:

https://doi.org/10.23960/jrsdd.v10i4.2857

Abstract Views: 2503 File Views: 937 File Views: 0

Abstract

Abstract

Turbidimeter is a standard instrument used to determine the level of turbidity of water. However, its use is felt to be less effective and efficient because it is not carried out in running water. Based on this statement, a practical suspended sediment measuring instrument based on a turbidity sensor is needed. Furthermore, to ensure the ability of a measuring instrument, an activity is needed to determine the validity of the conventional instrument reading value. Therefore, this study aims to calibrate the suspended sediment measuring instrument based on the turbidity sensor. The method used is to compare the measurement results of the design instrument against measuring standards that are traceable to international standards. Turbidity measurements were carried out using two devices which were compared at the same time.The results of the calibration show the output pattern with the appropriate level of linearity. The R-squared value which is the correlation coefficient, with R2=0.9667 indicates a good match between the two instruments. The slope gradient of the curve line is 1.1083 which means that the NTU-18 turbiditymeter is well calibrated. The results of the calculation of the unit conversion of NTU and mg/L have the average square of error or a correlation coefficient of R2=0.8984, meaning that both have a good correlation. In conclusion, the measuring instrument is able to operate properly and without problems. The tool manages to provide relative precision and practical response times, so work efficiency can be increased.

 

Keywords: Turbidity, Calibration, Convertion

Abstrak

Turbidimeter merupakan instrumen standar yang digunakan untuk menentukan taraf kekeruhan air. Namun penggunaannya dirasa kurang efektif dan efisien karena tidak dilakukan pada air mengalir. Berdasarkan pernyataan tersebut maka dibutuhkan instrumen ukur sedimen tersuspensi yang praktis berbasis turbidity sensor.Selanjutnya untuk memastikan kemampuan suatu alat ukur, maka diperlukanlah suatu aktifitas untuk menentukan keabsahan konvensional nilai pembacaan instrumen. Oleh karena itu, pada penelitian ini bertujuan untuk mengalibrasi alat ukur sedimen tersuspensi berbasis turbidity sensor. Metode yang digunakan pada penelitian ini yaitu dengan cara membandingkan hasil pengukuran alat rancangan terhadap standar ukur yang mampu telusur ke standar internasional. Pengkuran turbiditas dilakukan menggunakan dua alat yang dibandingkan pada waktu yang bersamaan.Hasil kalibrasi alat menujukkan pola output dengan tingkat linieritas yang sesuai. Nilai R-kuadrat yang merupakan koefisien korelasi, dengan R2=0,9667 menunjukkan kecocokan yang baik antara kedua instrumen. Gradien kemiringan garis kurva bernilai 1,1083 memiliki arti bahwa turbiditimeter NTU-18 sudah terkalibrasi dengan baik. Hasil perhitungan konversi satuan NTU dan mg/L memiliki kuadrat kesalahan rata-rata atau koefisien korelasi sebesar R2=0,8984, artinya keduanya memiliki korelasi yang baik. Kesimpulannya alat ukur mampu beroperasi dengan baik dan tanpa masalah. Alat berhasil memberikan presisi relatif dan waktu respons yang praktis, sehingga efisiensi pekerjaan dapat ditingkatkan.

 

Kata Kunci :Turbidity, Kalibrasi, Konversi

Downloads

Download data is not yet available.

References

Bardan, M., 2021. Analisis Pengaruh Lebar Saluran Kaca Pada Kedudukan Relatif Datar Terhadap Terjadinya Angkutan Sedimen. CivETech, 3 (2), 23–41.

Cahyadi, A., Ayuningtyas, E.A., dan Prabawa, B.A., 2013. Urgensi Pengelolaan Sanitasi Dalam Upaya Konservasi Sumberdaya Air Di Kawasan Karst Gunungsewu Kabupaten Gunungkidul. Indonesian Journal of Conservation, 2 (1), 23–32.

Faisal, M., Harmadi, dan Puryanti, D., 2016. Perancangan Sistem Monitoring Tingkat Kekeruhan Air Secara Realtime Menggunakan Sensor TSD-10. Jurnal Ilmu Fisika Universitas Andalas, 8 (1), 9–16.

Gemilang, W.A., Wisha, U.J., Rahmawan, G.A., dan Dhiauddin, R., 2018. Karakteristik Sebaran Sedimen Pantai Utara Jawa Studi Kasus: Kecamatan Brebes Jawa Tengah. Jurnal Kelautan Nasional, 13 (2), 65–74.

Ikhsan, M.A., Yahya, M., dan Fiolana, F.A., 2018. Pendeteksi Kekeruhan Air di Tandon Rumah Berbasis Arduino Uno. Jurnal Qua Teknika, 8 (2), 17–29.

Indra, S., Aditama, V., dan Yuwono, E., 2022. Penataan Kawasan Daerah Aliran Sungai Brangbiji Sumbawa Sebagai Sarana Wisata Kota Untuk Meningkatkan Ekonomi Masyarakat. Prosiding SEMSINA, 3 (1), 31–36.

Indriastuti, A. dan Nafiah, Z., 2017. Pengaruh Volume Perdagangan, Kurs dan Risiko Pasar Terhadap Return Saham. Jurnal STIE Semarang, 9 (1), 72–80.

International Standardization Organization, 2005. ISO/IEC 17025:2005 ‘General Requirements for The Competence of Testing and Calibration Laboratories’. Switzerland: ISO Org.

Kelley, C.D., Krolick, A., Brunner, L., Burklund, A., Kahn, D., Ball, W.P., dan Weber-Shirk, M., 2014. An Affordable Open-Source Turbidimeter. Sensors, 14 (4), 7142–7155.

Kurnia, R., Aminudin, A., dan Iryanti, M., 2019. Rancangan Sistem Alat Ukur Turbidity Untuk Monitoring Kekeruhan Air Kolam Tambak Udang. Seminar Nasional Fisika, 1 (1), 449–454.

Mulyanto, H.R., 2007. Sungai Fungsi dan Sifat-Sifatnya. Yogyakarta: Graha Ilmu.

Pangestu, H. dan Hakki, H., 2013. Analisis Angkutan Sedimen Total Pada Sungai Dawas Kabupaten Musi Banyuasin. Jurnal Teknik Sipil dan Lingkungan, 1 (1), 103–109.

Sudira, I.W., Mananoma, T., dan Manalip, H., 2013. Analisis Angkutan Sedimen Pada Sungai Mansahan. Jurnal Ilmiah Media Engineering, 3 (1), 54–57.

Susfalk, R.B., Fitzgerald, B., dan Knust, A.M., 2008. Suspended solids in the Upper Carson River, Nevada. Desert Research Institute, DHS, (Publication No. 41242), 61.

Wang, Y., Rajib, S.M.S.M., Collins, C., dan Grieve, B., 2018. Low-Cost Turbidity Sensor For Low-Power Wireless Monitoring Of Fresh-Water Courses. IEEE Sensors Journal, 18 (11), 4689–4696.

Zuraida, I., Wattini, dan Rasidi, H., 2018. Pengaruh Komposisi Media Filter Air Terhadap Permeabilitas dan Claritas. Jurnal Politeknologi, 17 (1), 97–106.

Downloads

Published

2022-12-10

How to Cite

Fakhrizal, A. B., Romdania, Y., Wahono, E. P., & Herison, A. (2022). Kalibrasi Alat Ukur Sedimen Tersuspensi Berbasis Turbidity Sensor. Jurnal Rekayasa Sipil Dan Desain, 10(4), Hal. 591 – 604. https://doi.org/10.23960/jrsdd.v10i4.2857

Issue

Section

Makalah Ilmiah Edisi Desember 2022