Studi Eksperimental Pengaruh Variasi Ukuran Recycled Coarse Aggregate (RCA) Terhadap Kuat Tekan dan Kuat Tarik Belah Beton Mutu Normal.

Authors

  • Nur Mila Putri Universitas Lampung
  • Laksmi Irianti
  • Surya Sebayang
  • Vera Agustriana Noorhidana

DOI:

https://doi.org/10.23960/jrsdd.v10i2.2607

Abstract Views: 72 File Views: 70 File Views: 0

Abstract

Abstract

Scattered concrete waste can cause adverse effects for the surrounding environment. It  must be recycled to reduce the waste, one of which is as a substitute for coarse aggregates of broken stones. To find out the feasibility of RCA concrete must be done material testing as well as testing of compressive strength and tensile strength using a cylinder test object measuring 15 x 30 cm. In this study, the materials used were RCA with a maximum aggregate size of 1 cm, 2 cm, and 4 cm which were randomly taken around the Materials and Construction Laboratory. So it is expected that unused concrete can be reused to reduce existing concrete waste. The results of 28-day split compressive strength for aggregate size of 1 cm on 28,99 MPa, 2 cm on 28,52 MPa, and 4 cm on 26,29 MPa. 28-day RCA size of 1 cm on 28,21 MPa, 2 cm on 27,72 MPa, and 4 cm on 25,09 MPa. The results of 28-day split tesnsile strength for 1 cm on 3,18 MPa, 2 cm on 2,81 MPa, and 4 cm on 2,58 MPa. 28-day RCA for aggregate size of 1 cm on 2,99 MPa, 2 cm on 2,48 MPa, and 4 cm on 2,31 Mpa. From these results, it is also known that the decrease in concrete testing results using RCA against splits is 2,69–4,56% for compressive strength and 5,97–10,47% for tesnsile strength.

Keyword: RCA, size, compressive strength, splitting tesnsile test.

 

Abstrak

Limbah beton yang berserakan dapat menyebabkan dampak buruk bagi lingkungan sekitar. Untuk mengurangi limbah tersebut harus dilakukan daur ulang, salah satunya yaitu sebagai pengganti agregat kasar pada beton. Untuk mengetahui kelayakan RCA tersebut harus dilakukan pengujian material serta pengujian kuat tekan dan kuat tarik belah pada beton dengan menggunakan benda uji silinder berukuran 15 x 30 cm. Pada penelitian ini, material yang digunakan yaitu RCA dengan ukuran maksimum agregat 1 cm, 2 cm, dan 4 cm yang diambil secara acak di sekitar Laboratorium Bahan dan Konstruksi. Diharapkan beton yang sudah tidak terpakai dapat digunakan kembali agar mengurangi limbah beton yang ada.Hasil pengujian kuat tekan beton 28 hari yang menggunakan split ukuran 1 cm sebesar 28,99 MPa, 2 cm sebesar 28,52 MPa, dan 4 cm sebesar 26,29 MPa. Pada beton RCA umur 28 hari untukukuran 1 cm sebesar 28,21 MPa, 2 cm sebesar 27,72 MPa, dan 4 cm sebesar 25,09 MPa. Hasil pengujian kuat tarik belah 28 hari pada beton yang menggunakan split ukuran 1 cm sebesar 3,18 MPa, 2 cm sebesar 2,81 MPa, dan 4 cm sebesar 2,58 MPa. Pada beton RCA umur 28 hari ukuran 1 cm sebesar 2,99 MPa, 2 cm sebesar 2,48 MPa, dan 4 cm sebesar 2,31 MPa. Dari hasil tersebut juga diketahui penurunan hasil pengujian beton RCA terhadap beton split yaitu sebesar 2,69 – 4,56% untuk kuat tekan dan 5,97 – 10,47% untuk kuat tarik belah.

Kata kunci: RCA, ukuran, kuat tekan, kuat tarik belah.

Downloads

Download data is not yet available.

References

ACI Committee 211, 1991. Standard Practice for Selecting Proportion Normal, Heavyweight, and Mess Concrete. American Concrete Institute.

ASTM C33, 2013. Standard Specification for Concrete Aggregates I. United States.

Bardosono, H. & Herbudiman, B., 2010. Pemanfaatan Beton Daur Ulang sebagai Substitusi Agregat Kasar pada Beton Mutu Tinggi. Bali: Konferensi Nasional Teknik Sipil, 4.

Kementerian PUPR, 2017. Rancangan Campuran Beton. Bandung: Diklat Perkerasan Kaku, 60.

Purwati, A., Shilihin, A., Sunarmasto., 2014. Pengaruh Ukuran Butiran Agregat Terhadap Kuat Tekan dan Modulus Elastisitas Beton Kinerja Tinggi Grade 80. Surakarta: e-Jurnal Matriks Teknik Sipil, 58.

Sadila, M & Idris, Y., 2019. Analisis Kuat Lentur Beton Agregat Daur Ulang Dengan Komposisi 35%, 50%, dan 100%. Banda Aceh: Journal of The Civil Engineering Student, 21–27.

SNI 7064, 2014. Semen Portland Komposit. Jakarta: Badan Standardisasi Nasional, 1–128.

SNI 03-2847, 2002. Tata Cara Perhitungan Struktur Beton Untuk Bangunan Gedung. Jakarta: Badan Standardisasi Nasional, 251.

SNI 1974, 2011. Cara Uji Kuat Tekan Beton dengan Benda Uji Silinder. Jakarta: Badan Standardisasi Nasional Indonesia, 20.

SNI 03-6861, 2002. Spesifikasi Bahan Bangunan Bagian A: Bahan Bangunan Bukan Logam. Jakarta: Badan Standardisasi Nasional Indonesia, 105-112.

SNI 03-2491, 2014. Metode Uji Kekuatan Tarik Belah Spesimen Beton Silinder . Jakarta: Badan Standardisasi Nasional Indonesia, 1–17.

SNI 03-6820, 2002. Spesifikasi Agregat Halus Untuk Pekerjaan Adukan dan Plesteran Dengan Bahan Dasar Semen. Jakarta: Badan Standardisasi Nasional, 6820.

Downloads

Published

2022-06-13

How to Cite

Putri, N. M., Irianti, L., Sebayang, S., & Noorhidana, V. A. (2022). Studi Eksperimental Pengaruh Variasi Ukuran Recycled Coarse Aggregate (RCA) Terhadap Kuat Tekan dan Kuat Tarik Belah Beton Mutu Normal. Jurnal Rekayasa Sipil Dan Desain, 10(2), Hal. 293 – 306. https://doi.org/10.23960/jrsdd.v10i2.2607

Issue

Section

Makalah Ilmiah Edisi Juni 2022