Pengaruh Serat Kulit Kayu Gelam Terhadap Kuat Tarik Lentur Beton Menggunakan Semen OPC

Authors

  • Herdi Awan
  • Caterina Niken DWSBU
  • Sasana Putra

DOI:

https://doi.org/10.23960/jrsdd.v8i2.1356

Abstract Views: 98 File Views: 64 File Views: 0

Abstract

The load from vehicles received by rigid pavement is characterized as dynamic load that move and change quantitively, so the r2eaction accepted by rigid pavement is the combination of compressive and tensile strength. In the reaserch, as the effort to know the effect of flexural and split tensile strength on normal quality concrete with 0%, 0,4%, 0,6% and 0,8%. The samples of flexural tensile strength testimonial use 60 cm x 15cm x 15 cm beam and the sampes of split tensile and compressive strength test use 15 cm x 30 cm cylinder.

 

As the result, the concrete sample with 0,4% of volume fraction has the most significant progress in the flexural tensile strength, split tensile strength and compressive strength. The result of this research also shows that the progress of flexural tensile test sample reach 9,42%, split tensile strength 7,5% and compressive strength 6,12% from concrete sample with 0% of volume fraction and it has decreased test result from 0,6% and 0,8% of volume fraction. The maximum of flexural tensile test, split tensile test, and compressive test are 6,62 MPa, 2,58 MPa, and 30,54 MPa.

 

Key words : Melaleuca bark fiber, flexural tensil strength,split tensil strength, compressive strength, volume fraction, and rigid pavement.

Downloads

Download data is not yet available.

References

ASTM C-39. Test for Specific Gravity and Absorption of Fine Aggregate. United States.

Purwanto, E. 1999. Perilaku Fiber Lokal pada Perilaku dan Kuat Torsi Ultimit Balok Beton Bertulang, Universitas Gajah Mada. Yogyakarta.

SNI 03-4431-1997.1997. Metode Pengujian Kuat Lentur Normal Dengan Dua Titik Pembebanan. Badan Standarisasi Nasional. Jakarta

SNI 2847-2013. 2013. Persyaratan Beton Struktural Untuk Bangunan Gedung. Badan Standarisasi Nasional. Bandung.

Tanudjaja, R.S, Windah H. 2015. Pengujian Kuat Tarik Lentur Beton dengan Variasi Kuat Tekan Beton. ISSN: 2337-6732, Manado .Vol.3 No. 5

Downloads

Published

2021-11-13

How to Cite

Awan, H., DWSBU, C. N., & Putra, S. (2021). Pengaruh Serat Kulit Kayu Gelam Terhadap Kuat Tarik Lentur Beton Menggunakan Semen OPC. Jurnal Rekayasa Sipil Dan Desain, 8(2), Hal. 385 – 394. https://doi.org/10.23960/jrsdd.v8i2.1356

Issue

Section

Makalah Ilmiah Edisi Juni 2020