Pengaruh Kejenuhan Air Tanah Lempung Organik Menggunakan Permodelan Laboratorium

Authors

  • Chintia Makki Lampung University
  • Setyanto Setyanto
  • Lusmeilia Afriani

DOI:

https://doi.org/10.23960/jrsdd.v5i2.788

Abstract Views: 76 File Views: 0

Abstract

The limited area for civil construction is affecting people to make building construction upper the clay- organic. The speciment of investigation soil wasobtained in Jabung, East Lampung. The speciment of soil obtaindirect shear and vane shear modeling test usingglass box with contain ±130,730gram/ 130,7kgof soil. Direct shear test for 30 cm depth below surfaceundrained soil obtainsomeresult.The result are forshearing strain is 0,1286 kg/cm2, shearing strain of vane shear test is 0,61 kg/cm2, and the value of bearing capacity is 1,4103 kg/cm2. for 50 cm depth below surfaceundrained soilintoobtain result for shearing strain is 0.1196 kg/cm2, shearing strain of vane shear test is 0,61 kg/cm2, and the value of bearing capacity is 1,7018 kg/cm2. Direct shear test for 30 cm depth below surfacedrained soilobtain result for shearing strain is 0,1286 kg/cm2, shearing strain of vane shear test is 0,61 kg/cm2, and the value of bearing capacity is 1,0347 kg/cm2 , for 50 cm depth below surfacedrained soilobtain result for shearing strain is 0,0861 kg/cm2, shearing strain of vane shear test is 0,46 kg/cm2, and the value of bearing capacity is 1,3997 kg/cm2 From the direct shear and vane shear test, it was obtained that shearingstrain in direct shear test is lower than vane shear test.

 

Keywords: Direct Shear Test, Vane Shear Test, Shearing Strain, The Clay-Organic, Bearing Capacity

Downloads

Download data is not yet available.

References

Hakim, Arief Rahman, 2014, Studi Modifikasi Alat Vane Shear Berdasarkan Variasi Tinggi Kipas, Universitas lampung, Bandar Lampung.

Hardiyatmo, Hary Christady, 1992, Mekanika Tanah I, PT. Gramedia Pustaka Utama, Jakarta.

Hardiyatmo, Hary Christady, 2002, Mekanika Tanah II, PT. Gramedia Pustaka Utama, Jakarta.

Das, Braja M., 1995, Mekanika Tanah Jilid I (Prinsip-prinsip Rekayasa Geoteknis), PT. Erlangga, Jakarta.

Terzaghi, K., Peck, R. B., 1987, Mekanika Tanah Dalam Praktek Rekayasa, Penerbit Erlangga, Jakarta

Published

2018-06-29

How to Cite

Makki, C., Setyanto, S., & Afriani, L. (2018). Pengaruh Kejenuhan Air Tanah Lempung Organik Menggunakan Permodelan Laboratorium. Jurnal Rekayasa Sipil Dan Desain, 5(2). https://doi.org/10.23960/jrsdd.v5i2.788

Issue

Section

Makalah Ilmiah Edisi Juni 2017