Pengaruh Perendaman Air Laut Terhadap Kuat Tekan dan Permeabilitas Beton
DOI:
https://doi.org/10.23960/jrsdd.v11i4.3840Abstract Views: 205 File Views: 233 File Views: 0
Abstract
Abstract
Concrete is one of the most commonly used building materials in infrastructure, including buildings in marine environments. This research aims to provide an overview of the strength of concrete due to exposure to sea water and compare it with protected concrete. The research was carried out experimentally using the SNI 03 - 2834 - 2000 mix design method by testing the compressive strength and permeability of concrete with a total of 30 test objects. The concrete is given a protected treatment and submerged in sea water. The results of research on the compressive strength of protected concrete aged 28, 56 and 90 days were 22, 56 MPa, 24.35 MPa and 25.84 MPa respectively. Meanwhile, the compressive strength of concrete submerged in sea water aged 28, 56 and 90 days is 22.27 MPa, 17.67 MPa and 16.10 MPa. Meanwhile, testing the permeability of concrete using the natural method (immersing the concrete in sea water) showed that the permeability of concrete aged 28, 56 and 90 days was 27.7 mm, 35.0 mm and 40.7 mm. The greater the permeability of the concrete, the smaller the compressive strength of the concrete and the smaller the permeability of the concrete, the greater the compressive strength value. Sea water can reduce the compressive strength of concrete based on the soaking time. In this case it is recommended when building construction in a marine environment to make the concrete watertight.
Key words : compressive strength, concrete, concrete permeability, sea water.
Abstrak
Beton adalah salah satu bahan bangunan yang paling umum digunakan dalam infrastruktur termasuk bangunan yang ada dalam lingkungan laut. Penelitian ini bertujuan untuk mengetahui gambaran mengenai kekuatan beton akibat terpapar oleh air laut dan membandingkan dengan beton terlindung. Penelitian dilakukan secara eksperimental dengan metode mix design SNI 03 – 2834 – 2000 dengan pengujian kuat tekan dan permeabilitas beton dengan jumlah benda uji sebanyak 30 sampel. Beton diberikan perlakuan terlindung dan terendam air laut. Diperoleh hasil penelitian kuat tekan beton terlindung umur 28, 56 dan 90 hari berturut – turut sebesar 22, 56 MPa, 24,35 MPa dan 25,84 MPa. Sedangkankuat tekan beton terendam air laut umur 28, 56 dan 90 hari sebesar 22,27 MPa, 17,67 MPa dan 16,10 MPa. Sedangkan pengujian permeabilitas beton menggunakan metode alami (merendam beton di air laut) diperoleh permeabilitas beton umur 28,56 dan 90 hari sebesar 27,7 mm, 35,0 mm dan 40,7 mm. Semakin besar permeabilitas beton maka akan semakin kecil kuat tekan beton dan semakin kecil permeabilitas beton maka nilai kuat tekan akan semakin besar. Air laut dapat menurunkan kuat tekan beton berdasarkan lama perendaman. Dalam hal ini disarankan dalam pembangunan kontruksi dilingkungan laut untuk membuat beton kedap air.
Kata kunci : air laut, beton, kuat tekan, permeabilitas beton.
Downloads
References
Akmaluddin, A., & Murtiadi, S. 2018. Struktur Balok Beton Bagian I Struktur Beton Bertulang. UPT. Mataram University. Mataram.
Anwar, C., Bachtiar, E., & Nur, N. K. 2019. Sifat Mekanik Beton Serat Ijuk yang Terendam Air Laut. Indonesian Journal of Fundamental Sciences Vol, 5(2).
ASTM, E. 178-02, Standard Practice for Dealing with Outlying Observations, 2002 Am. Soc. for Testing Materials.
Indriyanto, L. A., Saputra, A., & Sulistyo, D. 2020. Pengaruh Air Laut Pada Masa Perawatan Terhadap Infiltrasi Ion Klorida Pada Beton dengan Penambahan Fly Ash 12, 5%. Jurnal Riset Rekayasa Sipil, 3(2), 61-67.
Khonado, M. F., Manalip, H., & Wallah, S. E. 2019. Kuat Tekan dan Permeabilitas Beton Porous Dengan Variasi Ukuran Agregat. Jurnal Sipil Statik, 7(3).
Meliana, I. M., & Putri, B. A. S. K. 2022. Pengaruh Lingkungan Agresif Pada Beton Ditinjau Terhadap Kuat Tekan dan Absorpsi (Doctoral dissertation, Universitas Katholik Soegijapranata Semarang).
Prayuda, H., & Pujianto, A. 2018. Pengaruh Perawatan (Curing) Perendaman Air Laut dan Air Tawar Terhadap Kuat Tekan Beton. J. Ilm. Tek. Sipil, 22, 130-139
Rizky, C. B., & Saelan, P. 2019. Studi Mengenai Pengaruh Faktor Air-Semen dan Nilai Slump Beton Segar terhadap Permeabilitas Beton. Reka Racana: Jurnal Teknik Sipil, 5(4), 33.
SK SNI T-15-1990-03. 1990. Tata Cara Pembuatan Rencana Campuran Beton Normal. Yayasan Lembaga Penyelidikan Masalah Bangunan. Indonesia, 95.
SNI 03-2847. 2002. Tata Cara Perhitungan Struktur Beton Untuk Bangunan Gedung SNI 03-2847-2002. Bandung Badan Stand. Nas, 251.
SNI 15-2049. 2004.: Semen Portland. Badan Standardisasi Indonesia. Bandung.
SNI 1970. 2008. Cara Uji Berat Jenis dan Penyerapan Air Agregat Halus. BSN, Jakarta.
SNI 2847. 2013. Persyaratan beton struktural untuk bangunan gedung. Jakarta: Dewan Standarisasi Indonesia.
Susanto, D., Djauhari, Z., & Olivia, M. 2019. Karakteristik Beton Portland Composite Cement (PCC) Dan Silica Fume Untuk Aplikasi Struktur di Daerah Laut. Jurnal Rekayasa Sipil, 15(1), 1-11.
Wedhanto, S. 2017. Pengaruh Air Laut Terhadap Kekuatan Tekan Beton yang Terbuat dari Berbagai Merek Semen yang Ada di Kota Malang. Bangunan. 22(2), 21-30.
Wora, M., & Segu, Y. 2014. Pengaruh Waktu Perendaman Beton Dalam Air Laut Dapat Menurun Kualitas Beton. TEKNOSIAR, 8(2), 23-34.
Zulkarnain, F., & Kamil, B. 2021. Perbandingan Kuat Tekan Beton Menggunakan Pasir Sungai sebagai Agregat Halus Dengan Variasi Bahan Tambah Sica Fume Pada Perendaman Air Laut. In Prosiding Seminar Nasional Penelitian LPPM UMJ (Vol. 2021).
Downloads
Published
How to Cite
Issue
Section
License
JRSDD is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.