Analisis Variasi Layout Shearwall Dengan SNI 1726-2019 Terhadap Perilaku Bangunan Bertingkat (Studi Kasus: Gedung Pelayanan Publik Satu Atap Bandar Lampung)
DOI:
https://doi.org/10.23960/jrsdd.v11i2.3171Abstract Views: 175 File Views: 142 File Views: 0
Abstract
Earthquake resistant buildings are not designed only by strengthening the resistance of the structure, but are also designed to reduce earthquake forces. One of the structural reinforcement elements that can reduce earthquake forces is shearwall. The variation of shearwall layout will have a different effect on the performance level of the structure. This study aims to determine the performance level of the structure with a variety of shearwall layouts in a building structure model using the pushover analysis method. Determining the level of structural performance using pushover analysis is carried out using the help of structural analysis programs based on SNI 1726-2019, SNI 1727-2020, SNI 2847-2019 and ATC-40. From the research results it was found that the structural performance level according to ATC-40 (1996), for model 1 and model 6 were included in the damage control category, while for model 2, model 3, model 4 and model 5 were included in the immediate occupancy category. Placement of shearwall which has the optimum value according to ATC-40 for the X direction occurs in model 2 with the shearwall installed in an L shape which is placed near the center of mass of the building. Whereas in the Y direction it occurs in model 3 with the shearwall installed in an L shape which is placed away from the center of mass of the building.
Key words : shearwall, model, structure performance level, pushover analysis.
Downloads
References
ACI 374.2R-13. (2013). Guide for Testing Reinforced Concrete Structural Elements under Slowly Applied Simulated Seismic Loads. Farminton Hills: American Concrete Institute.
Andalas, G., Suyadi, & Hasti R. H. (2016). Analisis Layout Shearwall terhadap Perilaku Struktur Gedung. Jurnal Rekayasa Sipil Dan Desain (JRSDD), 1(1), 491–502.
Antonius. (2021). Perilaku Dasar Dan Desain Beton Bertulang Berdasarkan SNI-2847-2019. In Unissula Press.
ATC 40. (1996). Seismic Evaluation And Retrofit Of Concrete Buildings. California Seismic Safety Commission.
Kalangi, H. T., Tanijaya, J., & Michael Thetrawan. (2021). Analisis Pengaruh Penempatan Dinding Geser Terhadap Perilaku Dinamik Struktur Bangunan.
Kusuma, R. A., & Bambang Sabariman. (2022). Analisa Pengaruh Variasi Layout Shearwall Terhadap Kinerja Struktur Dengan Metode Pushover Analysis Pada Gedung Pelindo Office Tower. Jurnal Rekayasa Teknik Sipil, 4(2), 1–12.
Paulay, T., & Priestley, M. J. N. (1991). Seismic Design Of Reinforced Concrete And Masonry Buildings. John Wiley & Sons, INC.
Rezkiyanto, Mufti, & Imran. (2020). Penempatan Dinding Geser Pada Bangunan Beton Bertulang Dengan Analisa Pushover. Jurnal Ilmiah Media Engineering, 1(1), 31–39.
Sansujaya, E., Pah, J. J. S., & Udiana, I. M. (2021). Studi Kefektifan Dinding Geser pada Bangunan Tingkat Tinggi Dalam Mengurangi Simpangan Struktur. JURNAL FORUM TEKNIK SIPIL (J-ForTekS), 1(1), 24–34.
SNI 1726. (2019). Tata Cara Perencanaan Ketahanan Gempa Untuk Struktur Bangunan Gedung dan Non Gedung. Jakarta: Badan Standarisasi Nasional.
SNI 1727. (2020). Beban Desain Minimum Dan Kriteria Terkait Untuk Bangunan Gedung Dan Struktur Lain. Jakarta: Badan Standarisasi Nasional.
Usmat, N. A., Imran, & Mufti. (2019). Analisa Letak Dinding Geser (Shear Wall) Terhadap Perilaku Struktur Gedung Akibat Beban Gempa. Techno: Jurnal Penelitian, 8(2), 297–307.
Downloads
Additional Files
Published
How to Cite
Issue
Section
License
JRSDD is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.